Menu Setup
Motion Setup
• SENSITIVITY - Sets the Motion
Sensitivity. Press the
buttons to
navigate, and press the buttons
to set the values (min~max).
• VELOCITY - Sets the Motion Velocity.
Press the
buttons to navigate, and
press the
buttons to set the values
(min~max).
MASKING AREA - Turns on MASKING
for the specified area (by X,Y axis).
Press the
buttons to navigate, and
press the buttons to set the values.
• Press the MENU button to EXIT. All
settings will be saved.
Event Setup
Configuration for Alarm Reporting:
• ALARM - A report is generated when the
power is turned ON
• LOSS - A report is generated when a
camera has Signal Loss.
• MOTION - A report is generated when a
camera detects motion.
• BUZZER HOLD TIME - Sets the audible
buzzer time (when motion is detected)
between 0~99 seconds.
• REPORT HOLD TIME - Enables or
Disables the Report Hold time from
0~99 seconds
• ALARM POLARITY - Reports on the
Power On Alarm. Check off all 4 Alarm
Boxes, and set the POLARITY to HIGH.
If the POLARITY is set to LOW, the
POWER ON ALARM will not function.
MOTION SETUP
DETECTION TIME
ALWAYS ON
ON: 00:00
OFF: 13:00
SENSITIVITY: 0
VELOCITY: 0
MASKING AREA
X,Y (00,00)
⇑⇓ SELECT ⇐ ⇒ ADJUST MENU EXIT
CAMERA 1
EVENT REPORT
BUZZER / REPORT CONTROL
BUZZER HOLD TIME: 01 SEC
REPORT HOLD TIME: 01 SEC
ALARM POLARITY: LOW
CHANNEL
ALARM
LOSS
MOTION
1 2 3 4
⇐⇑⇓⇒ SELECT
ENTER DISABLE
MENU EXIT